SYSTEM RELIABILITY ANALYSIS OF ELECTRICITY DISTRIBUTION DUE TO DISTURBANCE DURING THR COVID-19 PANDEMIC AT PT. PLN (PERSERO) ULP SIDAREJA
Keywords:
Reliability, SAIFI, SAIDI, Disturbance, PLNAbstract
Electricity is the energy that is very needed by the society, mainly during the Covid-19 pandemic in now era, people are often stay at home because of PSBB (Large-Scale Social Restrictions), WFH (Work From Home) and online schools. Therefore, PLN is required to maintain the quality of electrical energy that is distributed to the customers. An electric power distribution system can be said to be reliable is if the disturbances and blackouts that occur in a certain period of time are below the specified reliability index number. A measure of the reliability in a system can be stated by calculating the SAIFI (System Average Interruption Frequency Index) and SAIDI (System Average Interruption Duration Index). The electric power distribution system in ULP Sidareja has a SAIFI value of 0,179 times/customer/year and SAIDI value of 0,199 hours/customer/year. The SAIFI and SAIDI value in ULP Sidareja is still below of the standard value which set by the SPLN 68-2-1986 standard, IEEE std 1366-2003 and WCS, furthemore the quality of the electricity distribution system in ULP Sidareja can be categorized as reliable.
References
[2] Republik Indonesia. 2020. Peraturan Pemerintah Republik Indonesia No. 21 Tahun 2020 tentang Pembatasan Sosial Berskala Besar dalam rangka percepatan penanganan corona virus disease 2019 (Covid-19). Jakarta: Kementerian Sekretariat Negara Republik Indonesia.
[3] Novelino,Andri. 2021. Konsumsi Listrik Naik 3,3 Persen per Maret 2021. Diakses pada 10 Juni 2021 melalui https://www.cnnindonesia.com/ekonomi/20210422182837-85-633589/konsumsi-listrik-naik-33-persen-per-maret-2021
[4] Mismail, B. 2011. Dasar Teknik Elektro Jilid 3 Sistem Tenaga dan Telekomunikasi. Malang:Universitas Brawijaya Press (UB Press). ISBN:978-602-8960-19-9.436 hal.
[5] Dasman, D., & Handayani, H. (2017). Evaluasi Keandalan Sistem Distribusi 20 kV Menggunakan Metode SAIDI dan SAIFI di PT. PLN (Persero) Rayon Lubuk Alung Tahun 2015. Jurnal Teknik Elektro, 6(2), 170-179.
[6] Funan, F., & Sutama, W. (2020). Evaluasi Keandalan Sistem Distribusi Tenaga Listrik Berdasarkan Indeks Keandalan SAIDI dan SAIFI pada PT PLN (PERSERO) Rayon Kefamenanu. JURNAL ILMIAH TELSINAS, 3(2), 32-36.
[7] Franklin, O., & Gabriel, A. (2014). Reliability analysis of power distribution system in Nigeria: a case study of Ekpoma network, Edo state. Int. Journal of Elect. Elect. Engin, 2(3).
[8] Syafar, M.2018. Penentuan Indeks Keandalan Sistem Distribusi 20Kv Dengan Metode FMEA (Failure Mode Effect Analysis). Makasar: Rizky Artha Mulia.
[9] Saputra, D. dkk. 2018. Analisis Indeks Keandalan dan Aspek Ekonomi Sistem Distribusi 20 Kv Penyulang J6 PT.PLN (Persero) UP3 Balikpapan. Samarinda: Universitas Mulawarman.
[10] Nurdiana, N. (2017). Studi Keandalan Sistem Distribusi 20 kV Gardu Induk Talang Ratu Palembang. Jurnal Ampere, 2(1), 23-30.
[11] Eminoglu, U., & Uyan, R. (2016). Reliability Analyses of Electrical Distribution System: A Case Study. International Refereed Journal of Engineering and Science, 5(12), 94-102.
[12] Aryanto, N., & Balkis, M. 2021.Tinjauan Gangguan Jaringan Distribusi 20 Kv Penyulang Muara Aman PT. PLN (Persero) Ulp Rayon Muara Aman. Jurnal Teknik Elektro Raflesia, 1(1), 16-22.
[13] Suswanto,D. 2009.Sistem Distribusi Tenaga listrik untuk Mahasiswa Teknik Elektro. Padang: Universitas Negeri Padang.
[14] Normalasari, D. 2010. Analisa Keandalan Sistem Distribusi Dengan Metode Reliability Index Assessment Pada Sistem Distribusi 20 Kv Di PLN APJ Jember. Jember: Universitas Jember.
[15] Marsudi, D.2006.Operasi Sistem Tenaga Listrik.Yogyakarta: Graha Ilmu.
[16] Hajar, dkk. (2018). Analisa Nilai SAIDI SAIFI Sebagai Indeks Keandalan Penyediaan Tenaga Listrik Pada Penyulang Cahaya PT. PLN (Persero) Area Ciputat. Jurnal Ilmiah Energi & Kelistrikan, 10(1), 70-77.
[17] Sodilesmana.E,A.2020. Analisis Ketidakseimbangan Beban Serta Pengaruh Pembebanan Transformator Distribusi Untuk Menentukan Susut Umur dan Sisa Umur. Bumiayu: Skripsi. Universitas Peradaban Bumiayu.
[18] Hasugian, D. A. P. (2020). Optimasi Penempatan Recloser Terhadap Keandalan Pada Sistem Distribusi Di PT. PLN (Persero) Kota Subulussalam, Aceh (Doctoral dissertation, UMSU).
[19] Siburian,J,M.dkk. (2020). Analisis Peningkatan Kinerja Jaringan Distribusi 20 kv Dengan Metode Thermovisi Jaringan PT. PLN (Persero) ULP Medan Baru. Jurnal Teknologi Energi Uda: Jurnal Teknik Elektro, 9(1), 8-19.
[20] Wahyudi, D. (2017). Evaluasi Keandalan Sistem Distribusi Tenaga Listrik Berdasarkan SAIDI Dan SAIFI Pada PT. PLN (Persero) Rayon Kakap. Jurnal Teknik Elektro Universitas Tanjungpura, 1(1).
[21] Sugiyono. 2017. Statistika untuk Penelitian. Bandung :C.V. Alfabeta.